Sales Integra Metering AG (formerly Aquametro) in Ukraine

You can contact us if you wish to receive tender about Integra Metering AG (formerly Aquametro) brand. Our company can provide optimal endustrial accessories supplies for you from overseas. We are not Ukraine distributor of Integra Metering AG (formerly Aquametro) brand yet we are importing it. We offer you a large order possiblity with our suitable supply coorperatives and supplying way.

Who is the official distributor or seller of Integra Metering AG (formerly Aquametro) in Ukraine?

Although we are not the official distributor or seller of Integra Metering AG (formerly Aquametro) in Ukraine, we source our products from reliable channels and offer original Integra Metering AG (formerly Aquametro) equipment at competitive prices.

Where can I buy Integra Metering AG (formerly Aquametro) products in Ukraine?

You can purchase Integra Metering AG (formerly Aquametro) products from ТОВ "ОДЕСА ТЕХНІК". We offer a wide range of original Integra Metering AG (formerly Aquametro) products to meet your industrial needs.

How can I access Integra Metering AG (formerly Aquametro) product catalogs, user manuals, technical documents, and PDFs?

You can access catalogs, user manuals, and technical documents for Integra Metering AG (formerly Aquametro) products on our website. Visit the resources section or contact us directly for specific documents.

Do you provide a warranty for Integra Metering AG (formerly Aquametro) products?

Warranty terms may vary depending on the product. Please contact us for detailed information about the warranty coverage of the Integra Metering AG (formerly Aquametro) products you are interested in.

How can I get technical support for Integra Metering AG (formerly Aquametro) products?

While we do not offer direct technical support, we can facilitate communication between you and the manufacturer to ensure you receive the necessary assistance.

Brand products Integra Metering AG (formerly Aquametro)

94604

PMW-basic 32 10._260_1 G1 / 4; Multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 260 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 12.7 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94606

PMWF-basic 32 10._150_1 G1 / 4 multi-jet vane hot water meter in glanded Thread connection: G 1 1/2 " Nominal size: DN 32 Mounting length: 150 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.1 m³ / h Permanent flow Q3: 10 m³ / h Maximum flow Q4: 12.5 m³ / h Kvs-value: 10.3 m³ / h Pressure loss in Q3: 900 mbar Measuring range: R 100 Inlet section: 0 x DN 32 Outlet flow: 0 x DN 32 Degree of protection: IP 66 Approval MI-001

94607

PMW-basic 16._300_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Thread connection: G 1 " Nominal size: DN 40 Mounting length: 300 mm Mounting position: horizontal Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0.16 m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 25.6 m³ / h Pressure loss in Q3: 400 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94608

PMWS-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical ascending Riser counter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 20.8 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

94609

PMWF-basic 16._200_1 40 1/2 ''; Multi-jet vane hot water meter in glanded Connection thread: G 2 " Nominal size: DN 40 Mounting length: 200 mm Mounting position: vertical falling Pipe meter Temperature max. 90 ° C. Nominal pressure: PN 16 Minimum flow Q1: 0,16m³ / h Permanent flow Q3: 16 m³ / h Maximum flow Q4: 20 m³ / h Kvs-value: 22.2 m³ / h Pressure loss in Q3: 600 mbar Measuring range: R 100 Inlet section: 0 x DN 40 Outlet flow: 0 x DN 40 Degree of protection: IP 66 Approval MI-001

96166.

CE test water meter R49 DN15-32

96167

CE test water meter R49 DN40-50

ART.NO. 80113/2008 AQUAPULS 1L

System module aquapuls® For retrofitting aquabasic® cold water meters. Pulse value 1 l / pulse with return compensation. Switching capacity 220 mA / 48 VDC. Degree of protection IP 68 with 1.5 m cable, fixed. With battery power

ART.NO. 83527 RV1/RD 20

DOMINO ® ARD structure group - Reguliergetriebe - Roller 6 digits, with RV Reed pulser, 48 VAC / DC, 50 mA, 2 W Specifications: Recording capacity Roller: 107 l Smallest readable Quantity: 0.1 l Pulse Value: 1 l

ART.NO. 92048 VZO 20 RC 130/16-RV1

CONTOIL® oil meter VZO 20 RC 130/16-RV 1 Ring piston meter for mineral oil, with rotatable roller counter

P/N 92280, VZF 50 FL 180/25

P/N 92280 Aquametro Oil Meter

P/N 94101

VZO 25 FL 180 / EXP 10-20K

P/N: 89763 VZO 4 -RE 0,00125

[CONTOIL ® fuel oil meters Reed pulser Pulse value 1.25 ml Nominal width: 4 mm With internal thread copper pipe: 1/8 " Nominal pressure: PN 25 Maximum permissible temperature: 50 ° C Mounting position: horizontal / vertical Largest flow Qmax. 80 l / h In continuous operation: 50 l / h Error of measurement: 1-80 l / h + / - 1% of the measurement error Recording capacity Roller 100 000 liters With built-on Reed pulser RE max:. 48V AC / DC, max. 50 mA, max. 3 VA Pulse value: 0.00125 l]

TMC19321

vzo-4 fuel counter

VCS04

MOTOR AC230V 50/60HZ DN25 WITH CAPACITOR AND GEAR FOR ACTUATOR TYPE: 2KN:

VZ020

fuel counter gear

VZ025

fuel counter gear

VZO 15 RC 130/16-RV0,1

(92042, CONTOIL® oil meter Reed pulser Pulse value 0.1 l, nominal width: 15 mm DN With 3/4 "thread for fittings: 1/2" Overall length: 165 mm Nominal pressure: PN 16 bar Max. Permissible temperature: 130 ° C Mounting position: horizontal / vertical Largest flow Qmax .: 600 l / h In continuous operation Qn .: 400 l / h Minimum flow rate Qmin .: 10 l / h Bias: 10-600 l / h ± 1% of reading Repeatability equal / better than 0.2% Total amount on roller 1 000 000 l Smallest readable Quantity: 0.01 l Pulser Reed, max.48 V AC / DC, 50 mA, 2 W Pulse value: 0.1 l Measuring principle: piston ring)

VZO 20 FL 130/25-IN0,01 91903

Oil meter with roller Measuring accuracy ± 1% Medium temperature to 130 ° C Roller counter with pulse generator, optionally Reed (RV) or Namur (IN) VZO 15 ... 50 with Flange EN 1092-1, PN 25

VZO-15

fuel meter

94606 PMWF-basic 32 10.-150-1 1/4"

TOPAS hot water meter, Nominal Size: DN 32,With thread 1 1/2 "(for screw 1 1/4"),Nominal pressure: PN 16 bar,Overall length: 150 mm,Mounting position: vertical falling,Temperature max .: 90 ° C,Overload flow Q4: 12.5 m3 / h,Permanent flow rate Q3: 10 m3 / h,Transition flow Q2: 12:16 m3 / h,Minimum flow rate Q1: 0.1 m3 / h,Measuring range: R 100,Smallest readable amount: 0.1 l,Registrable: 100000 m3,Measuring principle: multi-jet turbine, dry running

96158

CE test hydr. Encoder EN1434 DN15-32

92503

aquabasic® Kaltwasserzähler

96166 CE-Prüfung Wasserzähler R49 DN15-32

96166 CE-Prüfung Wasserzähler R49 DN15-32

92041 / VZO 15 RC 130/16

Oil meter with roller meter

Contact us for request